광·전기 변환부와 광 섬유 케이블이 일체화된 광 액티브 케이블. 서버나 스토리지 등의 정보 통신 간을 연결해 데이터센터의 처리능력 향상에 기여합니다.
Parameter | Target Specification | |
---|---|---|
Power consumption Per End | .9 Watt, typical | |
Connector | CXP with power, 84 Pin double card edges | |
Channels | 12 Channel, Duplex | |
Data Rate | Up to 120 Gbit/s (10 Gbit/s/ch) Tri-rate capable: InfiniBand SDR, DDR, QDR |
|
Latency (e-o-e conversions only) |
600 ps (typical) | |
Skew (max between 12 channels) |
40 ps (without fiber) | |
Operating Temperature | 0-70 degC | |
Storage temperature | -40 to 85 degC | |
Storage Humidity | 5-95% RH, non-condensing | |
Supply Voltages | +3.3 V | |
Link Bit Error Rate | < 10-15 | |
Data I/O | Differential AC-Coupled CML | |
Hot Pluggable | Yes | |
Cables types available | 1. LSZH (OFNR) 2. OFNP |
|
Compliance | NFPA 262 RoHS UL 1666 UL 60950-1 |
Class 1M laser product; Even if cable is cut FCC/EN55022(2006) Class B ESD: jedec HBM/MM, IEC 61000-4-2 |
Weight For 10-Meter Cable Assembly | < 300 grams typical | |
Cable Cross Section (without connector) | 4.5 mm | |
Tensile Strength | > 98 N | |
Cable length | Up to 100 m | |
Minimum Cable Bend Radius A) Exposed Connector Plus Cable 65 mm B) Cable Near Connectors 30 mm C) Central Section of Cable 100 mm |